TM 9-2320-366-34-4
18-6. 200 AMP ALTERNATOR REPAIR (CONT)
(10) Remove four screws (24), lockwashers (25), and cover
(26) from front housing (27). Discard lockwashers.
NOTE
Tag terminal lugs and connection points prior
to disconnecting.
(11) Remove adhesive, screw (28), lockwasher (29), washer
(30), terminal lugs (31 and 32) from 24 vdc post (33).
Discard lockwasher.
(12) Remove adhesive, screw (34), lockwasher (35), washer
(36), terminal lugs (37 and 38) from 12 vdc post (39).
Discard lockwasher.
18-64
Change 1