18-6. 200 AMP ALTERNATOR REPAIR (CONT)
(19) Remove adhesive, five screws (54), washers (55),
jumpers (56), and terminal lugs (57) from front housing
(27).
(20) Remove adhesive, screw (58), washer (59), jumpers (60
and 61), and terminal lug (62) from front housing (27).
(21) Match mark end housing (15) to stator (63).
(22) Remove nine self-locking nuts (64) and end housing (15)
from stator (63). Discard self-locking nuts.
(23) Remove bearing (65) from shaft (3).
(24) Remove bushing (66) from end housing (15). Discard
bushing.
(25) Remove six self-locking nuts (67) and washers (68) from
rotor (69). Discard self-locking nuts.
(26) Match mark rotor (69) to shaft (3).
(27) Install three jacking screws in small threaded holes in
rotor (69).
(28) Remove rotor (69) from shaft (3) by alternately turning
three jacking screws two full turns.
(29) Remove three jacking screws from rotor (69).
18-66