TM 9-2320-366-34-3
16-79. M1089 FLOWMETER VALVE ASSEMBLY REPLACEMENT/ADJUSTMENT (CONT)
(3) Remove eight self-locking nuts (6), 16 washers (7), eight
bolts (8), and floor plate (9) from support platform (10).
Discard self-locking nuts.
(4) Remove two studs (11) and caps (12) from support (13).
(5) Remove two studs (14), retainer (15), and caps (16) from
support (13).
16-482