TM 9-2320-366-34-3
16-79. M1089 FLOWMETER VALVE ASSEMBLY REPLACEMENT/ADJUSTMENT (CONT)
NOTE
Steps (10) through (12) require the aid of an
assistant.
(10) Extend stinger (4) (TM 9-2320-366-10-1).
NOTE
Stinger should retract in 6-8 seconds.
(11) Record time for stinger (4) to retract.
NOTE
Loosen set screw and turn flowmeter valve
left to decrease speed and right to increase
speed.
(12) Adjust upper flowmeter valve (5) , as required.
(13) Repeat steps (10) through (12), as required.
(14) Tighten setscrew (6).
d. Follow-On Maintenance.
(1) Check hydraulic fluid levels (TM 9-2320-366-10-2).
(2) Stow underlift (TM 9-2320-366-10-2).
End of Task.
16-486