TM 9-2320-366-34-3
(4) Remove two screws (5), four washers (6), two
lockwashers (7), nuts (8), and two way solenoid valve (2)
from control panel (9). Discard lockwashers.
(5) Remove 90-degree fitting (10) from two way solenoid
valve (2).
(6) Remove fitting (11) from two way solenoid valve (2).
(7) Remove preformed packings (12 and 13) from 90-degree
fitting (10). Discard preformed packings.
(8) Remove preformed packing (14 and 15) from fitting (11).
Discard preformed packings.
b. Installation.
(1) Install preformed packings (1 and 2) on 90-degree fitting
(3).
(2) Install preformed packings (4 and 5) on fitting (6).
(3) Install 90-degree fitting (3) and fitting (6) on two way
solenoid valve (7).
16-337