TM 9-2320-366-34-3
16-59. M1089 EIGHT-BANK VALVE ASSEMBLY REPLACEMENT/REPAIR (CONT)
WARNING
Crane control panel weighs approximately
150 lbs (68 kgs). Attach a suitable lifting
device prior to installation.
Failure to
comply may result in injury to personnel or
damage to equipment.
Adhesive Sealant MIL-S-46163 can damage
your eyes.
Wear safety goggles/glasses
when using; avoid contact with eyes.
If
sealant contacts eyes, flush eyes with water
and get immediate medical attention. Failure
to comply may result in injury to personnel.
(7) Apply sealing compound to threads of six bolts (11)
NOTE
Steps (8) and (9) require the aid of an
assistant.
(8) Position crane control panel (5) on vehicle with six
washers (12), bolts (11), and self-locking nuts (13).
(9) Tighten six self-locking nuts (13) to 43-47 lb-ft (58-64
N m).
(10) Connect eight hydraulic tubes (14) to valve manifold (2).
(11) Connect 11 hydraulic tubes (15) to valve manifold (2).
(12) Connect 13 solenoid electrical connectors (16) to valve
manifold (2).
16-334