TM 9-2320-366-34-3
(11) Remove connector cover (21) from portable worklight
connector (22).
(12) Remove nut (23), retaining plate (24), and portable
worklight connector (22) from support structure (6).
(13) Pull portable worklight connector (22) clear of support
structure (6).
(14) Disconnect two hydraulic hoses (25) from stiffleg cylinder
(26).
(15) Pull two hydraulic hoses (25) clear of support structure
(6).
(16) Disconnect air tube (27) from gladhand (28).
(17) Perform steps (6) through (16) on right side of support
structure.
15-149