TM 9-2320-366-34-3
WARNING
Adhesive sealant MIL-S-46163 can damage
your eyes.
Wear safety goggles/glasses
when using; avoid contact with eyes.
If
sealant contacts eyes, flush eyes with water
and get immediate medical attention. Failure
to comply may result in serious injury or
death to personnel.
(9) Apply sealing compound to threads of screw (11).
(10) Position bushing (12), washer (13), and screw (11) in
rivet eyebolt (10).
(11) Tighten screw (11) to 266-295 lb-ft (361-400 N·m).
(12) Position LH tension link cylinder (14) in boom assembly
(1) with pivot shaft (15).
(13) Install mast (16) in boom assembly (1) with pivot shaft
(15).
(14) Position RH tension link cylinder (17) in boom assembly
(1) with pivot shaft (15).
16-207