TM 9-2320-366-34-3(5) Install manual override valve (7) on crane control panel(8) with four washers (9), two lockwashers (10), bolts(11), and nuts (12).(6) Connect hose (13) to 90-degree fitting (6).(7) Connect tube (14) to fitting (3).(8) Connect connector (15) to manual override valve (7).c. Follow-On Maintenance.(1) Connect batteries (TM 9-2320-366-20-3).(2) Operate MHC and check for hydraulic leaks and forproper operation (TM 9-2320-366-10-1).End of Task.16-169