16-29. M1084/M1086 TWO WAY SOLENOID VALVE REPLACEMENT (CONT)
(5) Remove fittings (5 and 6) from two way solenoid valve
(2).
(6) Remove preformed packings (7 and 8) from fittings (5
and 6). Discard preformed packings.
b. Installation.
(1) Install preformed packings (1 and 2) on fittings (3 and 4).
(2) Install fittings (3 and 4) in two way solenoid valve (5).
(3) Install two way solenoid valve (5) on hydraulic tube (6).
(4) Connect hydraulic tube (7) to two way solenoid valve (5).
(5) Connect electrical connector (8) to two way solenoid
valve (5).
c. Follow-On Maintenance.
(1) Connect batteries (TM 9-2320-366-20-3).
(2) Operate MHC and check for hydraulic leaks at two way
solenoid valve (TM 9-2320-366-10-1).
End of Task.