TM 9-2320-366-34-2
7-7. STATIONARY CLUTCH SOLENOID ASSEMBLY REPLACEMENT/REPAIR (CONT)
WARNING
Use care when removing valve body
parts retained by retaining pins. Valve
body parts are under tension and can
act as projectiles when released. Failure
to comply may result in injury to
personnel.
(3) Remove retaining pin (4), stop (5), spring (6), and
valve (7) from clutch valve body (2).
CAUTION
Retaining pins must be removed from
bottom of solenoid body. Failure to comply
may result in damage to equipment.
(4) Remove three retaining pins (8), solenoids (9),
regulating valves (10), and springs (11) from clutch
valve body (2).
(5) Remove three preformed packings (12 and 13) from
solenoids (9). Discard preform packings.
c. Cleaning/Inspection.
WARNING
Dry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves;
use only in well-ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe
vapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint for
Type I Dry Cleaning Solvent is 100° F (38° C) and for Type II is 130° F (50° C). Failure to
comply may result in serious injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If dry cleaning solvent contacts skin or clothes, flush with cold water. If dry cleaning
solvent contacts eyes, immediately flush eyes with water and get immediate medical attention.
Failure to comply may result in serious injury or death to personnel.
(1) Clean all metal parts with dry cleaning solvent.
7-56