TM 9-2320-366-34-2
(7) Remove two bolts (16) and resilient mount (17) from
bracket (15).
d. RH Installation.
(1) Position resilient mount (1) on bracket (2) with two
bolts (3).
(2) Tighten two bolts (3) to 76-94 lb-ft (103-127 N·m).
NOTE
Steps (3) through (11) require the aid of an
assistant.
(3) Position bracket (3) on frame rail (4) with bolt (5) and
self-locking nut (6).
(4) Position bolt (7) in frame rail (4) with self-locking nut
(8).
(5) Tighten self-locking nuts (6 and 8) to 210-225 lb-ft
(285-305 N·m).
7-53