TM 9-2320-366-34-4
21-15. C7 CLUTCH HOUSING AND FRONT OUTPUT HOUSING ASSEMBLY REPAIR
(CONT)
(12) Remove bushing (18) and check ball (19) from C7 clutch
housing (11).
(13) Remove three manifold sealrings (20) from C7 clutch
housing (11). Discard sealrings.
b. Cleaning/Inspection.
WARNING
Dry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; use
only in well ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe vapors.
Keep away from heat or flame. Never smoke when using solvent; the flashpoint for Type I Dry
Cleaning Solvent is 100°F (38°C) and for Type II is 130°F (50°C). Failure to comply may result in
serious injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help.
If dry cleaning solvent contacts skin or clothes, flush with cold water. If dry cleaning solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention. Failure to comply may
result in injury to personnel.
(1) Clean all metal parts with dry cleaning solvent.
21-72