TM 9-2320-366-34-4
WARNING
Use care when removing retaining rings.
Retaining rings are under tension and can
act as projectiles when released. Failure
to comply may result in injury to
personnel.
(5) Apply pressure on spring retainer (8) in C6 clutch
housing (3).
(6) Remove retaining ring (9) from C6 clutch housing (3).
(7) Release pressure on spring retainer (8) in C6 clutch
housing (3).
(8) Remove spring retainer (8) from C6 clutch housing (3).
(9) Remove piston (10) and seal rings (11 and 12) from C6
clutch housing (3). Discard seal rings.
(10) Remove sleeve (13) from C6 clutch housing (3).
(11) Remove bushing (14) from sleeve (13).
b. Cleaning/Inspection.
WARNING
Dry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and
gloves; use only in well ventilated area; avoid contact with skin, eyes, and clothes, and do
not breathe vapors. Keep away from heat or flame. Never smoke when using solvent; the
flashpoint for Type I Dry Cleaning Solvent is 100°F (38°C) and for Type II is 130°F (50°C).
Failure to comply may result in serious injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If dry cleaning solvent contacts skin or clothes, flush with cold water. If dry
cleaning solvent contacts eyes, immediately flush eyes with water and get immediate medical
attention. Failure to comply may result in injury to personnel.
(1) Clean all metal parts with dry cleaning solvent.
21-67