TM 9-2320-366-34-316-32. M1089 MATERIAL HANDLING CRANE (MHC) REPLACEMENT (CONT)WARNINGAdhesive Sealant MIL-S-46163 can damageyour eyes. Wear safety goggles when using;avoid contact with eyes. If sealant contactseyes, flush eyes with water and getimmediate medical attention. Failure tocomply may result in injury to personnel.(3) Apply sealing compound to threads of six mounting bolts(4).(4) Position six washers (5), mounting bolts (4), spacers (6),washers (7), and nuts (8) in crane (3).(5) Tighten six nuts (8) to 857-929 lb-ft (1162-1260 N m).(6) Position two tubes (9) on hand pump (10).(7) Tighten two tubes (9) to 32-35 lb-ft (43-47 N m).(8) Position six tubes (11) on fittings (12).(9) Tighten six tubes (11) to 18-20 lb-ft (24-27 N m).16-178