TM 9-2320-366-34-2
6-4. FUEL SHUTOFF SOLENOID REPLACEMENT (CONT)
b. Installation.
(1) Install connector seal (1) on fuel shut-off solenoid (2).
(2) Install fuel shut-off solenoid (2) on governor (3).
(3) Position two electrical leads (4), lockwasher (5), and nut
(6) on fuel shut-off solenoid (2).
(4) Position electrical lead (7), lockwasher (8), and nut (9)
on fuel shut-off solenoid (2).
(5) Tighten nuts (6 and 9) to 23-27 lb-in. (3 N·m).
(6) Connect compressor inlet coolant tube (10) to air
compressor (11).
(7) Connect compressor inlet coolant tube (10) to thermostat
housing (12).
6-30
Change 1