TM 9-2320-366-34-2
6-2. 100 AMP ALTERNATOR REPAIR (CONT)
CAUTION
Nuts securing field leads and coil leads are
not interchangeable.
Tag field lead nuts
during removal. Failure to comply may result
in damage to equipment.
NOTE
Tag coil leads and connection points prior to
disconnecting.
(9) Remove six nuts (25), coil leads (26), and washers
(27) from front housing (9).
(10) Match mark end housing (21) to stator (17).
(11) Remove nine self-locking nuts (28) and end housing
(21) from stator (17). Discard self-locking nuts.
(12) Remove bearing (29) from shaft (3).
(13) Remove three screws (30), lockwashers (31), and
washers (32) from rotor (33). Discard lockwashers.
(14) Install three jacking screws in small threaded holes
on rotor (33).
(15) Remove rotor (33) from shaft (3) by alternately
turning three jacking screws two full turns.
(16) Remove three jacking screws from rotor (33).
6-4