TM 9-2320-366-34-3
(35) Remove two spring pins (58), roller shafts (59), and
cable guide sheaves (60) from base mounts (19).
Discard spring pins.
(36) Remove two bushing (61) from cable guide sheaves
(60).
c. Cleaning/ Inspection.
WARNING
Dry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and
gloves; use only in well ventilated area; avoid contact with skin, eyes, and clothes, and do
not breathe vapors. Keep away from heat or flame. Never smoke when using solvent; the
flashpoint for Type I Dry Cleaning Solvent is 100°F (38°C) and for Type II is 130°F (50°C).
Failure to comply may result in serious injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If dry cleaning solvent contacts skin or clothes, flush with cold water. If dry
cleaning solvent contacts eyes, immediately flush eyes with water and get immediate medical
attention. Failure to comply may result in serious injury or death to personnel.
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use only with
effective chip guarding and personal protective equipment (goggles/shield, gloves, etc).
Failure to comply may result in injury to personnel.
NOTE
Replace any part that fails to pass visual inspection or size measurement requirements.
(1) Clean all metal parts with dry cleaning solvent.
16-546
16-88. 15K SELF-RECOVERY WINCH (SRW) ASSEMBLY REPLACEMENT/REPAIR (CONT)