TM 9-2320-366-34-3
NOTE
Lightly lubricate all parts prior to installation.
(58) Apply antiseizing tape to threads of four 90-degree
fittings (75) and fittings (76).
(59) Install four 90-degree fittings (75) in lower control valve
assembly (46).
(60) Install four fittings (76) in lower control valve assembly
(46).
(61) Install preformed packing (77) on adapter (78).
(62) Install adapter (78) in lower control valve assembly (46).
(63) Install eight preformed packings (79) on adapters (80).
(64) Install eight adapters (80) in lower control valve
assembly (46).
(65) Install preformed packing (81) on adapter (82).
(66) Install adapter (82) in lower control valve assembly (46).
(67) Install tee fitting (83) in adapter (82).
(68) Install two preformed packings (84) on plugs (85).
(69) Install two plugs (85) in lower control valve assembly
(46).
e. Installation.
NOTE
Step (1) requires the aid of an assistant.
(1) Install lower control valve assembly (1) on control panel
(2) with three screws (3), six washers (4), and three nuts
(5).
Change 1
16-516.13/(16-516.14 Blank)