CONTINUITY TEST
CAUTION
(1) Loosen screw in adapter cable 24-pin
connector.
(2) Disconnect adapter cable 24-pin connector
from internal wiring harness 24-pin
connector.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter
to adapter cable 31-pin connector pin N.
(5) Connect negative (-) probe of multimeter
to adapter cable 24-pin connector pin G2
and note reading on multimeter.
(6) If continuity is not present, replace
transmission adapter cable assembly
(para 6-8).
(7) Connect positive (+) probe of multimeter
to adapter cable 31-pin connector pin N.
(8) Connect negative (-) probe of multimeter
to all other pins in adapter cable 31-pin
connector and note reading on multimeter.
(9) Connect negative (-) probe of multimeter
to ground and note reading on multimeter.
Use care when disconnecting wiring harness
connectors. Failure to comply may result in
damage to equipment.
(10) If continuity is present, transmission
adapter cable assembly is shorted; replace
transmission adapter cable assembly
(para 6-8).