Change 1 2-135TM 9-2320-366-34-1CONTINUITY TESTCAUTION(1) Loosen screw in adapter cable 24-pinconnector.(2) Disconnect adapter cable 24-pin connectorfrom internal wiring harness 24-pin connector.(3) Set multimeter to ohms.(4) Connect positive (+) probe of multimeterto adapter cable 31-pin connector pin N.(5) Connect negative (-) probe of multimeterto adapter cable 24-pin connector pin G2and note reading on multimeter.(6) If continuity is not present, replacetransmission adapter cable assembly (para 6-8).(7) Connect positive (+) probe of multimeter to adapter cable 31-pin connector pin N.(8) Connect negative (-) probe of multimeter to all other pins in adapter cable 31-pinconnector and note reading on multimeter.(9) Connect negative (-) probe of multimeter to ground and note reading on multimeter.Use care when disconnecting wiring harnessconnectors. Failure to comply may result indamage to equipment.(10) If continuity is present, transmission adapter cable assembly is shorted; replace transmission adapter cable assembly (para 6-8).