TM 9-2320-366-34-4
26-5. M1084\M1086\M1089 HOIST HYDRAULIC MOTOR REPAIR (CONT)
(13) Remove gasket (16) from motor housing flange (15).
Discard gasket.
(14) Remove preformed packing (17), seal (18), and retainer
(19) from motor housing flange (15). Discard preformed
packing, seal, and retainer.
(15) Remove motor housing (1) from vise.
(16) Remove output shaft (2) from motor housing (1).
(17) Remove inner bearing ring (20) and roller retainer (21)
from output shaft (2).
b. Cleaning/Inspection
WARNING
Dry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves;
use only in well ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe
vapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint for Type
I Dry Cleaning Solvent is 100°F (39°C) and for Type II is 130°F (50°C). Failure to comply may
result in serious injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes,
immediately flush eyes with water and get immediate medical attention. Failure to comply may
result in serious injury or death to personnel.
Compressed air used for cleaning purposes will not exceed 30 psi (207 Kpa). Use only with
effective chip guarding and personal protective equipment (goggles/shield, gloves, etc).
Failure to comply may result in injury to personnel.
(1) Clean all metal parts with dry cleaning solvent and dry with compressed air.
26-28