TM 9-2320-366-34-3
f. Adjustment.
NOTE
Left and right 30K winch relief valves are
adjusted the same way. Left side shown.
(1) Disconnect hose (1) from fitting (2).
(2) Install plug (3) in hose (1).
(3) Install reducer (4) on fitting (2).
WARNING
Use care in placement of STE/ICE-R
instruments
used
to
perform
these
adjustments. Hydraulic system pressures
are approximately 3000 PSI.
Hoses will
move or jump under this pressure. Secure
test instruments, as required.
Failure to
comply may result in injury to personnel or
damage to equipment.
(4) Connect test hose (5) to reducer (4).
(5) Install 10,000 PSI transducer on test hose (5).
(6) Connect 10,000 PSI transducer to STE/ICE-R.
(7) Open hydraulic reservoir supply valve and return valve
(TM 9-2320-366-10-2).
(8) Start engine (TM 9-2320-366-10-1).
(9) Position PTO switch to ON (TM 9-2320-366-10-1).
(10) Increase engine speed to 1250-1450 RPM (TM 9-2320-
366-10-1).
Change 1
16-391