M1089 MATERIAL HANDLING CRANE (MHC) BOOM DOES NOT TELESCOPE IN OR OUT (CONT) - TM-9-2320-366-34-1_1193
M1089 MATERIAL HANDLING CRANE (MHC) HOIST DOES NOT WORK

TM-9-2320-366-34-1 M1078 Series 2 1/2-Ton 4x4 Light Medium Tactical Vehicles (LMTV) Manual
Page Navigation
  1118    1119    1120    1121    1122  1123  1124    1125    1126    1127    1128  
TM 9-2320-366-34-1 TELESCOPIC CYLINDER LOAD TEST HOLDING VALVE CHECK (1)  Pick up light load with MHC, extend boom       (tele-out) and lift boom to 30 degrees       (TM 9-2320-366-10-1). (2)  Load test (para 16-62). If cylinder drifts, holding       valve on telescopic cylinder is faulty. (1)  Perform M1089 crane load test (para 16-62).       Telescopic cylinder shall maintain position       for 30 minutes. (2)  If telescopic cylinder drifts in less than 30       minutes, replace telescopic cylinder (para 16-37). (3)  Stow MHC (TM 9-2320-366-10-1). 2-1061