TM 9-2320-366-34-3
NOTE
Perform step (17) on M1093 and M1094.
(17) Install six button plugs (23) in two door posts (24).
NOTE
Perform step (18) on all models except
M1093 and M1094.
(18) Install two button plugs (25) in door posts (24).
NOTE
Left and right side door seals, check valve
boots, and door strike catch plates are
installed the same way. Left side shown.
(19) Position catch strike plate (26) on door post (24) with
threaded plate (27), shim (28), and three screws (29).
(20) Tighten three screws (29) to 70-85 lb-in. (8-10 N·m).
(21) Install ventilation check valve boot (30) in door post (24).
(22) Install door seal (31) on cab (2).
(23) Perform steps (19) through (22) on right side door seals,
check valve boot, and door catch strike plate.
15-31