TM 9-2320-366-34-2
a. Removal.
CAUTION
Cap or plug hoses and connection points to
prevent contamination of hydraulic system.
Failure to comply may result in damage to
equipment.
NOTE
Tag hoses and connection points prior to
disconnecting.
Remove plastic cable ties as required.
(1) Disconnect hose (1) from fitting (2).
(2) Disconnect hose (3) from fitting (2).
(3) Disconnect hose (4) from fitting (5).
(4) Disconnect hose (6) from fitting (5).
(5) Remove nuts (7 and 8) and fittings (2 and 5) from
subframe (9).
(6) Remove self-locking nut (10), clamps (11 and 12), and
screw (13) from subframe (9). Discard self-locking nut.
(7) Remove two self-locking nuts (14), clamps (15), and
screws (16) from subframe (9). Discard self-locking
nuts.
13-351