TM 9-2320-366-34-2
(131) Position coolant fill hose (176) on hose fitting (177) with
clamp (178).
(131.1) Tighten clamp (178) to 34-44 lb-in. (4-5 N·m).
CAUTION
Ensure hoses and connection points are
tagged correctly prior to disconnecting.
Failure to comply may result in air system not
being able to pressurize.
(132) Connect two unloader valve hoses (179) to adapters
(34).
(133) Connect air compressor pressure hose (180) to 90-
degree fitting (35).
(134) Install air compressor intake hose (181) on 45-degree
fitting (182) with clamp (183).
(135) Install coolant bypass hose (184) on coolant tube (31)
with clamp (185).
Change 1