Change 1 2-195
TM 9-2320-366-34-1
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to adapter cable 31-pin connector pin A.
(3) Connect negative (-) probe of multimeter
to adapter cable 24-pin connector pin A2
and note reading on multimeter.
(4) If continuity is not present, replace
transmission adapter cable assembly
(para 6-8).
(5) Connect positive (+) probe of multimeter
to adapter cable 31-pin connector pin A.
(6) Connect negative (-) probe of multimeter
to all other pins in adapter cable 31-pin
connector and note reading on multimeter.
(7) Connect negative (-) probe of multimeter
to ground and note reading on multimeter.
(8) If continuity is present, transmission
adapter cable assembly is shorted; replace
transmission adapter cable assembly
(para 6-8).
(9) Connect external wiring harness 31-pin
connector to adapter cable 31-pin
connector.
CONTINUITY TEST