Change 1 2-187
TM 9-2320-366-34-1
RESISTANCE TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to A solenoid connector pin A.
(3) Connect negative (-) probe of multimeter
to A solenoid connector pin B and note
reading on multimeter.
(4) If resistance is less than 2.5 ohms or
more than 5.0 ohms, replace A solenoid
(para 7-8).
(5) If resistance is between 2.5-5.0 ohms,
replace WTEC II TEPSS (TM 9-2320-366-
20-4).
(6) Connect internal wiring harness connector A
to A solenoid connector.
(7) Install cover on control valve module with
four screws.
(8) Install control valve module (para 7-10).
(9) Connect batteries (TM 9-2320-366-20-3).