Change 1 2-103
TM 9-2320-366-34-1
RESISTANCE TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to pin 1 of turbine speed sensor.
(3) Connect negative (-) probe of multimeter
to pin 2 of turbine speed sensor and note
reading on multimeter.
(4) If resistance is less than 200 ohms or
greater than 400 ohms, replace
transmission turbine speed sensor
(para 6-5).
(5) If resistance is between 200 and
400 ohms, replace WTEC II TEPSS
(TM 9-2320-366-20-4).
(6) Connect internal wiring harness connector
TSS to turbine speed sensor.
(7) Install cover on control valve module with
four screws.
(8) Install control valve module (para 7-10).
(9) Connect adapter cable 24-pin connector to
internal wiring harness 24-pin connector.
(10) Tighten screw in adapter cable 24-pin
connector.
(11) Connect batteries (TM 9-2320-366-20-3).