Change 1 2-1072.11PRESSURE TEST (1) Disconnect hose B from fitting at port B of valve manifold.(2) Install swivel run tee on fitting at port B of valve manifold.(3) Connect hydraulic hose B to swivel run tee.(4) Connect adapter, hose, and STE/ICE adaptorto swivel run tee.(5) Start engine (TM 9-2320-366-10-1).(6) Position PTO switch to on (TM 9-2320-366-10-1).(7) Increase engine RPM to 1250-1450 (TM 9-2320-366-10-1). (8) Press and hold DUMP BED UP/DOWN switch in the DOWN position until hydraulic oil temperature reaches 145°F-155°F (63°C-68°C).(9) Perform STE/ICE Test #51 (TM 9-4910-571-12&P) Holding DUMP BED UP/DOWN switch in the down position will force hydraulic oil through relief valve and cause oil temperature to rise.Measure hydraulic oil temperature nearbottom of hydraulic reservoir.NOTEHydraulic oil temperature must be 145°F-155°F (63°C- 68°C) prior to performing troubleshooting checks. Failure to complymay result in inaccurate test results. CAUTION Lubricating oil is slippery and can cause falls.Wipe up spilled oil with rags. Failure to complymay result in injury to personnel.Prolonged contact with lubricating oil (MIL-L-2104) may cause a skin rash. Skin and clothing that come in contact with lubricating oil should be thoroughly washed immediately. Saturated clothing should be removed immediately. Areasin which lubricating oil is used should be well ventilated to keep fumes to a minimum. Failure to comply may result in injury to personnel.Wear approved eye protection when performing pressure checks. Failure to comply may result in oil getting into eyes. If oil contacts eyes,seek medical attention immediately.Dump body weighs approximately 3,030 lbs. (1,376 kgs). Attach a suitable lifting device prior to lifting. Failure to comply may result ininjury to personnel.WARNINGPRESSURE TEST (Cont)TM 9-2320-366-34-1(10) Hold DUMP BED UP/DOWN switch in the DOWN position and observe pressurereading of 325-375 psi (2241-2586 kPa). If pressure is low, adjust pressure reducingvalve clockwise. If pressure is high, adjust pressure reducing valve counterclockwise. If pressure cannot be adjusted, clean or replace pressure reducing valve (para 17-3).(11) Reduce engine RPM to idle (TM 9-2320-366-10-1).(12) Position PTO switch to off (TM 9-2320-366-10-1).(13) Shut down engine (TM 9-2320-366-10-1). (14) If pressure can be adjusted, but dumpbed still does not raise, replace hoistcylinder (para 17-4). (15) Remove STE/ICE adaptor, hose and adapter from swivel run tee.(16) Remove hose B from swivel run tee.(17) Remove swivel run tee from port B of valve manifold.(18) Connect hose B to port B of valve manifold.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business