TM 9-2320-366-34-1
Wear appropriate eye protection when
working under vehicle due to the
possibility of falling debris. Failure
to comply may result in injury to personnel.
Maintain engine rpm at 1,250-1,450 rpm
while performing pressure and flow tests.
Failure to comply may result in damage to
equipment.
HYDRAULIC FLOW AND PRESSURE TEST
CAUTION
WARNING
(14) Shut down engine (TM 9-2320-366-10-1).
(15) Disconnect pressure hose from hydraulic tester
at pressure port (P) of winch control valve.
(16) Disconnect pump supply pressure hose from
hydraulic tester.
(17) Connect pump supply pressure hose to port (P)
on winch control valve.
(18) Remove drain pan from under winch control
valve.
(1) Position drain pan under winch control valve.
(2) Disconnect pump supply pressure hose from
pressure port (P) on winch control valve.
(3) Connect pressure hose to hydraulic tester.
(4) Connect pressure hose from hydraulic tester
to pressure port (P) of winch control valve.
(5) Completely open hydraulic tester load valve.
(6) Start and run engine until normal operating
temperature is reached (TM 9-2320-366-10-1).
(7) Engage PTO (TM 9-2320-366-10-1).
(8) Increase engine RPM to 1250-145- RPM
(TM 9-2320-366-10-1).
(9) Slowly close load valve on hydraulic tester
until 2450-2600 psi (16893-17927 kPa) is
reached and note flow on hydraulic tester.
(10) If flow is not 15-18 GPM (57-70 lpm) at
2450-2600 psi, replace hydraulic rotary
pump (para 16-91).
(11) Open load valve on hydraulic tester.
(12) Decrease engine speed (TM 9-2320-366-10-1).
(13) Position PTO switch to off
(TM 9-2320-366-10-1).
2-1021