TM 9-2320-366-34-1
2-996
CAUTION
WARNING
Wear approved eye protection when
performing pressure checks. Failure
to comply may result in oil getting
into eyes. If oil contacts eyes, seek
medical attention immediately.
Fuel and oil are slippery and can
cause falls. Wipe up spilled fuel
or oil with rags. Failure to comply
may result in injury to personnel.
Exercise caution when operating
stiffleg. Failure to comply may
cause hoses to rub against
stiffleg causing damage to
equipment.
(Continued from previous page)
UPPER MAIN CONTROL VALVE
PRESSURE/FLOW TEST (CONT)
(5) Connect hydraulic tester to hydraulic system:
(a) Connect test hoses to pressure and
reservoir ports of hydraulic tester.
(b) Connect pressure test hose to right stiffleg
extend hose.
(c) Connect reservoir test hose to right stiffleg
retract hose.
NOTE
Steps (6 through 8) require the aid
of an assistant.
(Continued on next page)
Drop hydraulic pressure to zero
before disconnecting any
hydraulic hose, tube, or fitting.
Failure to comply may result
in injury to personnel.
(6) Start engine (TM 9-2320-366-10-1).
(7) Position PTO switch to on (TM
9-2320-366-10-1).
(8) Increase engine RPM to 1250-1450 RPM (TM
9-2320-366-10-1).
(9) Position RIGHT STIFFLEG control valve handle
DOWN.
(10) Perform flow test and note reading.
(11) Perform pressure test and note reading.
(12) If flow and pressure are below 12 gpm and
2400 psi, repair or replace upper main
valve assembly (para 16-83).
(13) If flow and pressure are 12 gpm and 2400-3000
psi, repair or replace right stiffleg cylinder
(para 16-68).
h3. M1089 RIGHT STIFFLEG DRIFTS OR DOES NOT WORK (CONT)