TM 9-2320-366-34-3
(7) Disconnect hose A (7) from fitting (8).
(8) Install cap (9) on fitting (8).
(9) Install plug (10) in hose A (7).
(10) Install 10,000 PSI transducer on test hose (6).
(11) Connect 10,000 PSI transducer to STE/ICE-R.
(12) Start engine (TM 9-2320-366-10-1).
(13) Position PTO switch to on (TM 9-2320-366-10-1).
(14) Increase engine speed to 1250-1450 RPM (TM 9-2320-
366-10-1).
(15) Attach temperature indicator label to hydraulic reservoir
(11).
Change 1
17-15