TM 9-2320-366-34-3
(10) Install two back-up rings (12) and preformed packings
(13 and 14) on pressure reducing valve (15).
(11) Position pressure reducing valve (15) in valve body (5).
(12) Tighten pressure reducing valve (15) to 35-40 lb-ft (41-
47 N·m).
(13) Install back-up ring (16) and preformed packings (17 and
18) on check valve (19).
(14) Position check valve (19) in valve body (5).
(15) Tighten check valve (19) to 35-40 lb-ft (41-47 N·m).
(16) Install four back-up rings (20) and three preformed
packings (21) on relief valve (22).
(17) Position relief valve (22) in valve body (5).
(18) Tighten relief valve (22) to 35-40 lb-ft (41-47 N·m).
Change 1
17-14.9