TM 9-2320-366-34-3
(41) Position hose (69) to fitting (70).
(42) Position two hoses (71) on tee fittings (66).
(43) Tighten hoses (65, 67, 69, and 71) to 38-42 lb-ft (52-57
N·m).
(44) Pull up on regulating valve knob (72) and turn knob fully
to the right.
(45) Push in on regulating valve knob (72).
f. Follow-On Maintenance.
(1) Connect batteries (TM 9-2320-366-20-3)
(2) Install catwalks (TM 9-2320-366-20-3).
(3) Open hydraulic reservoir supply valve and return valve
(TM 9-2320-366-10-2).
(4) Install 30K winch cables (TM 9-2320-366-20-5).
(5) Adjust 30K winch tensioner pneumatic valves (para 16-
66).
(6) Operate 30K winches and check for proper operation
and hydraulic leaks (TM 9-2320-366-10-2).
16-375