TM 9-2320-366-34-3
(3) Disconnect eight hydraulic tubes (4) from valve manifold
(2).
WARNING
Crane control panel weighs approximately
150 lbs (68 kgs). Attach a suitable lifting
device prior to removal. Failure to comply
may result in injury to personnel or damage
to equipment.
(4) Remove six self-locking nuts (5), washers (6), and bolts
(7) from three corners of crane control panel (8).
Discard self-locking nuts.
NOTE
Step (5) requires the aid of an assistant.
(5) Remove crane control panel (8) from vehicle.
(6) Remove hydraulic tube (9) from valve manifold (2) and
accumulator (10).
(7) Remove three hydraulic tubes (11) from back of valve
manifold (2).
NOTE
Step (8) requires the aid of an assistant.
(8) Remove eight bolts (12), lockwashers (13), washers (14),
and valve manifold (2) from crane control panel (8).
Discard lockwashers.
(9) Remove eight knobs (15) from levers (16).
16-313