Figure 1-21. Material Handling Crane (MHC) System
Figure 1-23. M1089 Underlift System

TM-9-2320-366-34-1 M1078 Series 2 1/2-Ton 4x4 Light Medium Tactical Vehicles (LMTV) Manual
Page Navigation
  24    25    26    27    28  29  30    31    32    33    34  
TM 9-2320-366-34-1 Figure 1-22.   Troubleshooting Aid i.  Troubleshooting Aid.   A start inhibit switch (1, Figure 1-22), located on the Power Distribution Panel (PDP) (2), is provided  as  a  troubleshooting  aid  for  the  Unit  and  DS  Maintenance  levels  and  as  a  maintenance  tool  at  the  GS Maintenance level to stop fuel flow at the fuel shutoff solenoid (3).   By pressing the start inhibit switch first, the starter pushbutton (4) can be pressed and the engine cranked without allowing the engine to be started.   The start inhibit switch is reset when the master power switch is positioned to off and then to on again. 1-29