TM 9-2320-366-34-1 2-1102 KNOWN INFO REASON FOR QUESTION TEST OPTIONS 2. Does boom remain in position under load? KNOWN INFO TEST OPTIONS REASON FOR QUESTION YES 3. Fault corrected. NO NO YES Holding Valve Check Faulty holding valve. Faulty telescopic cylinder. Replace telescopic cylinder (para 16-5). Does telescopic cylinder work smoothly without leaking? Telescopic Cylinder Load Test Faulty telescopic cylinder will cause boom to not telescope in or out. Faulty telescopic cylinder. POSSIBLE PROBLEMS POSSIBLE PROBLEMS Hydraulic oil level OK. Hydraulic hoses, tubes, and fittings OK. Control valve OK. Tele out lockout valve OK. Holding valve OK. Hydraulic oil level OK. Hydraulic hoses, tubes, and fittings OK. Control valve OK. Tele out lockout valve OK. Faulty holding valve will cause telescopic cylinder to drift down. Replace telescopic cylinder (para 16-5). l7.  M1084/M1086 MATERIAL HANDLING CRANE (MHC) BOOM DOES NOT TELESCOPE IN OR OUT (CONT)