M1084/M1086 MATERIAL HANDLING CRANE (MHC) HYDRAULIC TROUBLESHOOTING
INPUT FLOW RATE TEST - TM-9-2320-366-34-1_1222

TM-9-2320-366-34-1 M1078 Series 2 1/2-Ton 4x4 Light Medium Tactical Vehicles (LMTV) Manual
Page Navigation
  1145    1146    1147    1148    1149  1150  1151    1152    1153    1154    1155  
TM 9-2320-366-34-1 2-1074 Materials/Parts   Rag, Wiping (Item 60, Appendix C)   Hose (2) (Item 40, Appendix C)   Fitting (2) (Item 31, Appendix C)   Adapter, Swivel (Item 3, Appendix C)   Reducer, Tube (Item 61, Appendix C)   Adapter, Pipe (Item 1, Appendix C)   Adapter, Pipe (Item 2, Appendix C) Personnel Required   (2) l1.  M1084/M1086 MATERIAL HANDLING CRANE (MHC) HYDRAULIC FUNCTIONS OPERATE       SLOWLY INITIAL SETUP   Equipment Conditions    Engine shut down (TM 9-2320-366-10-1).   Tools and Special Tools     Tool Kit, Genl Mech (Item 78, Appendix B)     Tester, Hydraulic (Item 73, Appendix B)     Pan, Drain (Item 43, Appendix B)     Goggles, Industrial (Item 28, Appendix B)             KNOWN INFO              Hydraulic oil level OK. PTO OK. Hydraulic hoses, tubes, and fittings OK.        POSSIBLE PROBLEMS        Faulty hydraulic rotary pump. Faulty manual override valve. Faulty input check valve. Faulty main relief valve. Faulty two-way solenoid valve. 1. WARNING Read WARNING on following page. START Is input flow rate OK?            TEST OPTIONS            Input Flow Rate Test     REASON FOR QUESTION     Faulty hydraulic rotary pump or manual override valve will cause low pressure to control valve assemblies. NO YES Replace hydraulic rotary pump (para 16-91) or manual override valve (para 16-30).







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.