• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
PRESSURE TEST - TM-9-2320-366-34-1_1211
PRESSURE TEST - TM-9-2320-366-34-1_1213

TM-9-2320-366-34-1 M1078 Series 2 1/2-Ton 4x4 Light Medium Tactical Vehicles (LMTV) Manual
Page Navigation
  1136    1137    1138    1139    1140  1141  1142    1143    1144    1145    1146  
k1. DUMP BODY DOES NOT RAISE            TEST OPTIONS                        KNOWN INFO              Is hydraulic pressure at least 2500 PSI at input port P of valve manifold? TM 9-2320-366-34-1 2-1072.8          Change 1 Faulty winch control valve will cause dump body not to raise.     REASON FOR QUESTION     Pressure Test or STE/ICE-R Test #51 Hydrualic oil level OK.            PTO OK. Hydrualic Rotary pump OK.        POSSIBLE PROBLEMS        Faulty relief valve. Faulty pressure reducing valve. Faulty hoist cylinder. Faulty M1090/M1094 four way relief valve. 7. Go to step 3 of this fault. NO YES Replace winch control valve TM 9-2320-366-20-4 (para 17-25).







Western Governors University

Privacy Statement
Press Release