  1129    1130    1131    1132    1133  1134  1135    1136    1137    1138    1139  
Change 1          2-1072.1 TM 9-2320-366-34-1 PRESSURE TEST       (1) Disconnect hose from fitting at output port        A of valve manifold.   (2) Install cap on output port A of valve        manifold.   (3) Install plug on output hose A.   (4) Start engine (TM 9-2320-366-10-1).   (5) Position PTO switch to on (TM 9-2320-       366-10-1)   (6) Increase engine RPM to 1250-1450        (TM 9-2320-366-10-1). CAUTION Hydraulic oil temperature must be 145°F- 155°F (63°C-68°C) prior to performing troubleshooting checks.  Failure to comply may result in inaccurate test results. NOTE Holding DUMP BED UP/DOWN switch in the down position will force hydraulic oil through relief valve and cause oil temperature to rise. Measure hydraulic oil temperature near bottom of hydraulic reservoir. (12) Remove STE/ICE adapter, hose, and        reducer from swivel run tee. (13) Disconnect hose P from swivel run tee. (14) Remove swivel run tee from 90 degree        fitting at input port P of valve manifold. (15) Connect hose to 90 degree fitting at input        port P of valve manifold. (16) Remove plug from port A hose. (17) Remove cap from output port A of valve        manifold. (18) Connect hose to port A fitting of valve        manifold.   (7) Press and hold DUMP BED UP/DOWN        switch in the DOWN position until hydraulic        oil temperature reaches 145°F-155°F        (63°C-68°C).   (8) Perform STE/ICE Test #51 (TM 9-4910-        571-12&P)     (9) Hold DUMP BED UP/DOWN switch in        the UP position and observe pressure        reading of 2475-2525 psi (17065-17410        kPa).  If pressure is low, adjust relief        valve clockwise.  If pressure is high,        adjust relief valve counterclockwise.          If pressure cannot be adjusted, clean        or replace relief valve (para 17-3). (10) Position PTO switch to off (TM 9-2320-        366-10-1). (11) Shut down engine (TM 9-2320-366-        10-1).        







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.