TM 9-2320-366-34-1 NO YES KNOWN INFO 3. REASON FOR QUESTION TEST OPTIONS Flow and Pressure Test CAUTION Read CAUTION and WARNING on following page. WARNING POSSIBLE PROBLEMS Replace M1089 three stage hydraulic pump (para 16-92). Hydraulic oil level OK. Hydraulic hoses, tubes, and fittings OK. 15K self-recovery winch electric circuit OK. Hydraulic oil tank, filters and strainers OK. 15K self-recovery winch control valve assembly OK. Faulty 15K self-recovery winch counterbalance valve. Faulty 15K self-recovery winch cartridge valve. Faulty 15K self-recovery winch hydraulic motor. Faulty self-recovey winch assembly. Faulty M1089 three stage hydraulic pump. Is there 15-18 GPM (51-70 lpm) at 2450-2600 psi (16893-17927 kPa) measured at output of M1089 three stage hydraulic pump? If M1089 hydraulic pump flow and pressure is not correct, three stage hydraulic pump is faulty. i1.  15K SELF-RECOVERY WINCH DOES NOT WORK (CONT) 2-1022